SAFETY PRECAUTIONS
—Read All Instructions Before Using The Meter—
Always wear eye protection when testing vehicles. Be extra careful near
batteries and moving parts. Do not lay tools on a battery.
Battery gas is highly explosive.
a. If a battery explodes flush the acid away from persons skin with
generous amounts of water. Follow up with a neutralizing solution of
baking soda and then more water.
Treat clothing, vehicle parts, and equipment similarly. Any acid traces
inside equipment must be removed by generous rinsing. Dry
equipment and place in a warm 50°C (120°F) oven until thoroughly
dry.
b. Never use a wrench on the ungrounded battery terminal until the
grounded one has been disconnected. Contact between the vehicle
body metal and the hot terminal can cause sparks to ignite gas or
even weld tools into a battery short circuit.
c. Keep the space around a battery well ventilated.
d. Do not make sparks or allow flames near batteries.
Before working on a vehicle set the brakes and block the wheels. Beware
of automatic parking brake releases.
Keep your work area well ventilated and free of exhaust. Engine exhaust
contains deadly poisons. Treat Gas Detector exhaust and drain hoses
the same as the vehicle tailpipe. Both give off deadly exhaust fumes.
•Avoid electrical shocks caused by getting close to live ignition wires or
touching the coil TACH terminal. A person’s reaction near a live engine
can be more damaging than the shock.
Keep spark producing devices at least 0.5m (18”) above the floor to reduce
the hazard of igniting gasoline vapor.
Do not let test leads wind up in a moving fan or pulley. Route leads away.
Remove finger rings and metal wrist bands. They can short terminals and
become very hot from electric current.
Technical Support & Service
Warranty
Questions or inquiries about service can be answered by contacting Ferret at:
(231) 627-5664, Fax: (231) 627-2727, Toll Free (800) 627-5655. When sending an
item to the factory address it to:
Ferret Instruments, Inc., 1310 Higgins Dr., Cheboygan, MI 49721-1061 Include a
note describing the problem.
FERRET BRAND LIMITED PRODUCT WARRANTY
FERRET INSTRUMENTS, INC. of Cheboygan Michigan, warrants to the original
purchaser that FERRET brand products are free from defects in materials and
workmanship for a period of three years from date of purchase. Our sole obligation
for a product within the above warranties will be to repair or replace, at our option,
any defective parts and return the product to the sender within the U.S.A., shipping
prepaid, if it is sent to our Repair Department shipping prepaid and accompanied by
proof of purchase.
The above warranty is extended for the flashtubes in timing lights which are within
five years of the date of manufacture.
EXTENDED SERVICE POLICY
A FERRET brand product less than five years old according to the date of
manufacture, and which is returned with transportation charges prepaid to: Ferret
Instruments, Inc., Repair Department, 1310 Higgins Drive, Cheboygan, MI 49721,
will be repaired or replaced, at factory option, for a service charge not to exceed
40% of the latest factory suggested user price; plus return transportation charges
and insurance. If the product has been discontinued, the nearest equivalent product
may be substituted.
This Warranty and Extended Service Policy do not apply to products which have
been altered outside the factory; or repaired by anyone other than the factory or its
authorized service centers; or which have been damaged from accidents, negligence,
or abuse; or have been used differently than described in the printed instructions.
Please note that wear and tear on leads and replacement of consumable items,
such as NOX and O2 Sensors, is not covered by warranty.
Ferret Instruments, Inc.'s sole liability and buyer's exclusive remedy is limited to
repair or replacement of the product as stated in the Limited Product Warranty and
the Extended Service Policy. THERE ARE NO OTHER WARRANTIES EXPRESSED
OR IMPLIED INCLUDING THOSE OF MERCHANTABILITY OR FITNESS FOR A
PA RTICULAR PURPOSE AND FERRET INSTRUMENTS, INC. SHALL NOT BE
LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE
SALE OR USE OF THE PRODUCT.
Some states do not allow limitations on the length of implied warranties nor exclusion
or limitations of incidental or consequential damages, so that the above limitations
and/or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other rights
which may vary from state to state.
E950-01
OPERATOR’S MANUAL
©Copyright 2001, Ferret Instruments, Inc.
TM
Labscope KV
Adapter
950
BNC to
Banana
Adapter
Introduction
The Ferret 950 adapts virtually any dual channel labscope or graphing multimeter to display
Kilovolts on both DIS and Conventional ignition systems. The ignition waveform will be
displayed in a parade pattern. Labscopes that do not have a Cylinder #1 Trigger will need to
use the Ferret 951 Cylinder #1 Trigger in conjunction with the Ferret 950 to properly synchronize
the parade pattern.
The quality of the ignition waveform depends on the performance of the labscope.
General Instructions
You must be familiar with the operation of the labscope being used with the Ferret 950.
Please refer to the operator’s manual for the labscope if necessary. All instructions contained
in this manual are written for the Ferret 950’s use on a dual output (two cylinders per coil)
distributorless ignition system. On a typical Double Output DIS system, you will have half of
the connectors plugged into the Red side of the Ferret 950, and the other half plugged into
the Blue side.
The Ferret 950 uses a 9-volt battery for power. When you turn the Ferret 950 on, the battery
indicator LED will illuminate. Be sure to turn the unit off when finished with testing.
Single Trace LabScopes
Some single trace labscopes are able to display ignition waveforms. You must connect both
the Cylinder #1 Trigger (Ferret 951), and the Ferret 950 to the input channel by stacking the
banana jacks. Since the Trigger is on the same channel as the Ferret 950, Cylinder #1 will
have a very high spike. Set the trigger to pickup just the top portion of the spike. This will
synchronize the display to #1 Cylinder. To analyze Cylinder #1, move the Ferret 951 Cylinder
#1 Trigger to another cylinder.
Distributor Ignitions
All instructions remain the same, except you connect only one KV Clip to the Coil wire. Do
not connect KV Clips to each individual spark plug wire. Simply plug the single KV Lead into
either a Blue or Red connector. For Distributor ignitions where the coil is in the cap, you will
need the appropriate KV Pickup Plate found in the Available Accessories Section.
Coil per Plug Ignitions
All instructions remain the same, except you will use only the Blue or Red connectors on the
front panel of the Ferret 950. For engines with more than 4 cylinders, you will need an X020-
43 Adapter. One adapter for every 2 additional cylinders. With a standard Ferret 950 you
can check a 4 cylinder Coil per Plug ignition without the need for adapters. You will need 1,
X020-43 for a 6 cylinder engine, and 2, X020-43’s for an 8 cylinder engine.
Available Accessories
Ferret 951 Cylinder #1 Trigger
X020-43 10 Cylinder Adapter Kit/Coil Per Plug Adapter Kit
X020-44 KV Pickup Plate for GM HEI Internal Coil Ignitions
X020-45 KV Pickup Plate for Toyota Internal Coil Ignitions
X020-46 KV Pickup Plate for Nipondenso Internal Coil Ignitions.
X015-05 KV Pickup Plate for BMW Coil per Plug Ignitions
BNC Cable
Battery
Compartment
Groun
Lead
Power
Switch &
Indicator
KV
Clips