Introduction
The Ferret 953 adapts virtually any dual channel labscope or graphing multimeter to display
Kilovolts on both DIS and Conventional ignition systems. The ignition waveform will be
displayed in a parade pattern. Labscopes that do not have a Cylinder #1 Trigger will need to
use the Ferret 951 Cylinder #1 Trigger in conjunction with the Ferret 953 to properly synchronize
the parade pattern.
The quality of the ignition waveform depends on the performance of the labscope.
General Instructions
You must be familiar with the operation of the labscope being used with the Ferret 953. Please
in this manual are written for the Ferret 953’s use on a dual output (two cylinders per coil)
distributorless ignition system. On a typical Double Output DIS system, you will have half of
the connectors plugged into each side of the Ferret 953. Use the polarity switches on the 953
to set the fi ring polarity the same (COP Ignitions), or each side different (DIS Ignitions).
The Ferret 953 uses a 9-volt battery for power. Press the Power button once and the indicator
light will be constantly on. After 5 minutes the 953 will power down. Press the Power button
a second time and the 953 will stay on until the battery runs down, or you turn it off.
Single Trace LabScopes
Some single trace labscopes are able to display ignition waveforms. You must connect both
the Cylinder #1 Trigger (Ferret 951), and the Ferret 953 to the input channel by stacking the
banana jacks. Since the Trigger is on the same channel as the Ferret 953, Cylinder #1 will
have a very high spike. Set the trigger to pickup just the top portion of the spike. This will
synchronize the display to #1 Cylinder. To analyze Cylinder #1, move the Ferret 951 Cylinder
#1 Trigger to another cylinder.
Distributor Ignitions
All instructions remain the same, except you connect only one KV Clip to the Coil wire. Do not
connect KV Clips to each individual spark plug wire. Simply plug the single KV Lead into any
connector. For Distributor ignitions where the coil is in the cap, you will need the appropriate
KV Pickup Plate found in the Available Accessories Section.
Coil per Plug Ignitions
Connect one spark wire clip to each coil. Set the polarity switches to the same polarity on
both sides.
Available Accessories
Ferret 951 Cylinder #1 Trigger
X020-44 KV Pickup Plate for GM HEI Internal Coil Ignitions
X020-45 KV Pickup Plate for Toyota Internal Coil Ignitions
X020-46 KV Pickup Plate for Nipondenso Internal Coil Ignitions.
X015-05 KV Pickup Plate for BMW Coil per Plug Ignitions
Safety Precautions
Read all Instructions before using the device
Always wear eye protection when testing vehicles. Be extra careful near
batteries and moving parts. Do not lay tools on a battery.
Battery gas is highly explosive.
a. If a battery explodes ush the acid away from persons skin with generous
amounts of water. Follow up with a neutralizing solution of baking soda
and then more water.
Treat clothing, vehicle parts, and equipment similarly. Any acid traces
inside equipment must be removed by generous rinsing. Dry equipment
and place in a warm 50°C (120°F) oven until thoroughly dry.
b. Never use a wrench on the ungrounded battery terminal until the
grounded one has been disconnected. Contact between the vehicle
body metal and the hot terminal can cause sparks to ignite gas or even
weld tools into a battery short circuit.
c. Keep the space around a battery well ventilated.
d. Do not make sparks or allow fl ames near batteries.
Before working on a vehicle set the brakes and block the wheels. Beware
of automatic parking brake releases.
Keep your work area well ventilated and free of exhaust. Engine exhaust
contains deadly poisons. Treat Gas Detector exhaust and drain hoses the
same as the vehicle tailpipe. Both give off deadly exhaust fumes.
Avoid electrical shocks caused by getting close to live ignition wires or
touching the coil TACH terminal. A person’s reaction near a live engine can
be more damaging than the shock.
Keep spark producing devices at least 0.5m (18”) above the oor to reduce
the hazard of igniting gasoline vapor.
Do not let test leads wind up in a moving fan or pulley. Route leads
away.
Remove fi nger rings and metal wrist bands. They can short terminals and
become very hot from electric current.
Technical Support & Service
Technical Support & Service
Warranty
Questions or inquiries about service can be answered by contacting GxT, Inc., at:
Toll Free (800) 627-5655.
Fax: (231) 627-2727, Toll Free (231) 782-0616, or
When sending an item to the factory address it to:
GxT, Inc., 520 MM Riggs Drive., Cheboygan, MI 49721-1061
Include a note describing the problem.
FERRET BRAND LIMITED PRODUCT WARRANTY
GxT, Inc. of Cheboygan Michigan, warrants to the original purchaser that
FERRET brand products are free from defects in materials and workman-
ship for a period of two years from date of purchase. Our sole obligation for a
product within the above warranties will be to repair or replace, at our option,
any defective parts and return the product to the sender within the U.S.A.,
shipping prepaid, if it is sent to our Repair Department shipping prepaid and
accompanied by proof of purchase.
This Warranty does not apply to products which have been altered outside the
factory; or repaired by anyone other than the factory or its authorized service
centers; or which have been damaged from accidents, negligence, or abuse;
or have been used differently than described in the printed instructions. Please
note that wear and tear on leads and replacement of consumable items such
as: NOx Sensors, Oxygen Sensors, and paper, is not covered by warranty.
GxT Inc.ʼs sole liability and buyerʼs exclusive remedy is limited to repair or
replacement of the product as stated in the Limited Product Warranty. THERE
ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUD-
ING THOSE OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE AND GxT, INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES ARISING FROM THE SALE OR USE OF
THE PRODUCT.
Some states do not allow limitations on the length of implied warranties nor
exclusion or limitations of incidental or consequential damages, so that the
above limitations and/or exclusion may not apply to you.
This warranty gives you specifi c legal rights and you may also have other
rights which may vary from state to state.
E953-01G
©Copyright 2005, GxT, Inc., All Rights Reserved
Single Trace LabScopes
Distributor Ignitions
Coil per Plug Ignitions
OPERATORʼS MANUAL
LabScope KV Adapter
953
BNC
Cable
BNC to Banana
Adapter
Battery
Compartment
Ground
Lead
Power
Button
KV
Clips
Vue de la page 0
1 2

Résumé du contenu

Page 1 - LabScope KV Adapter

IntroductionThe Ferret 953 adapts virtually any dual channel labscope or graphing multimeter to display Kilovolts on both DIS and Conventional i

Page 2

KalScope 575, Mac Tools 2020, 2020-2If you have any problems viewing an ignition pattern, set up the Ferret 953 and the labscope using the instruction

Commentaires sur ces manuels

Pas de commentaire