3
Ranges & Accuracy
Accuracy is give as ± ([% of reading] + [number of least significant digits]) at
18°C to 28°C with relative humidity up to 80%, for a period of one year after
calibration.
Function Range Resolution Accuracy Input Impedance
DC Volts 200mV 100µV 0.5% + 1 digit 10MΩ
2V 1mV 0.5% + 1 digit 10MΩ
20V 20V 0.5% + 1 digit 10MΩ
200V 0.1V 0.5% + 1 digit 10MΩ
1000V 1V 0.5% + 1 digit 10MΩ
AC Volts 200mV 100µV 0.8% + 3 digits 10MΩ
2V 1mV 0.8% + 3 digits 10MΩ
20V 10mV 0.8% + 3 digits 10MΩ
200V 0.1V 0.8% + 3 digits 10MΩ
750V 1V 1.2% + 3 digits 10MΩ
Function Range Resolution Accuracy Voltage Drop
DC Amps 200µA 0.1µA 0.8% + 1 digit 1mV/µA
2mA 1µA 0.8% + 1 digit 100mV/µA
20mA 10µA 0.8% + 1 digit 10mV/mA
200mA 100µA 0.8% + 1 digit 1.2mV/mA
2A 1mA 0.8% + 1 digit 0.28V/A
10A 10mA 2.0% + 10 digits 0.22V/A
AC Amps 200µA 0.1µA 0.8% + 3 digits 1mV/µA
2mA 1µA 0.8% + 3 digits 100mV/µA
20mA 10µA 0.8% + 3 digits 10mV/mA
200mA 100µA 0.8% + 3 digits 1.2mV/mA
2A 1mA 0.8% + 3 digits 0.28V/A
10A 10mA 2.0% + 10 digits 0.22V/A
Function Range Resolution Accuracy Open Circuit
Voltage
Ohms 200Ω 0.1Ω 0.5% + 10 digits < 1.2 V
2KΩ 0.5% + 1 digit < 1.2 V
20KΩ 10Ω 0.5% + 1 digit < 1.2 V
200KΩ 0.1KΩ 0.5% + 1 digit < 1.2 V
2MΩ 1KΩ 0.5% + 1 digit < 1.2 V
20MΩ 10KΩ 1.0% + 2 digits < 1.2 V