7
Big Digit Screen
Press either the Up or Down select buttons to alternate between
the composite, Grams per Mile and Big Digit screens. The big digit
screen displays the five gases and RPM in a large format. Press
the NEXT button to go to the main selection screen.
Grams Per Mile Screen
Press either the Up or Down select buttons to alternate between
the composite, Grams per Mile and Big Digit screens. The Grams
Per Mile Screen displays the estimated grams per mile of all gases.
This calculation is based on the miles per gallon constant that is
set using the Engine Setup function. Combustion Efficiency is also
calculated on this screen. It is displayed as CE. A number of .995
indicates the combustion efficiency is at 99.5% Use combustion
efficiency with lambda to see if there is an adequate fuel charge
and ignition in the combustion process. Press the NEXT button to
go to the main selection screen.